Aeris CompuMask HUD Operating Manual

Download PDF user manual for Aeris CompuMask HUD (Heads-up Display) (EN) 149 pages Doc. No. 12-7220-r01 (9/12/07) 2007 zip

SKU: AERISCOMPUMASKUM Category: Brand:

Description

This PDF operating manual is for the Aeris CompuMask HUD.

Aeris CompuMask HUD (Heads-up Display)

It is extremely important that you read this Operating Manual in sequence and understand it completely before attempting to use the CompuMask as a dive computer.

It is equally important that you read the AERIS Dive Computer Safety and Reference Manual (Doc. No. 12-7203) provided with your CompuMask. It contains information that you must become familiar with prior to diving with your CompuMask.

Remember that technology is no substitute for common sense, and a dive computer only provides the person using it with data, not the knowledge to use it.

The documents listed below are for reference only. For specific operational details, consult the original paper documents included with your product.

(PDF) OPERATING MANUAL (EN)

CONTENTS:

– Full LCD
– Warranty, Notices, Decompression Model
– FCC ID

INTRODUCTION AND GENERAL FEATURES AND DISPLAYS
– General Interface and Human Factors
– Mask Optics and Display Interface
– Environmental Capabilities
– Interactive Control Console
– Operating Mode Structure
– Audible Alarm
– Backlight
– Power Supply
– Bar Graph
– PC Interface
– Alpha / Numeric Displays. Tank Pressure Display. Depth Displays. Air Time Remaining Display. Time, Date, and Temperature Displays.

SURFACE SEQUENCE AND OPERATING MODES
– Operating Modes
– Surface Mode. NOR (Normal) Surface Main Display. NOR Surface Main Button Operations. Transmitter Low Battery.
– Set Modes
– Set G Group (Backlight). Set Backlight Level.
– SET F GROUP (FO2)
– How to set FO2 for NOR Nitrox Dives
– How to set FO2
– How to set FO2 50% Default.
– SET A GROUP (NOR/GAU ALARMS)
– How to set Audible Alarm
– How to set Depth Alarm
– How to set EDT (Elapsed Dive Time) Alarm
– How to set TLBG (Tissue Loading Bar Graph) Alarm
– How to set DTR (Dive Time Remaining) Alarm
– How to set Turn Pressure Alarm
– How to set End Pressure Alarm
– How to set PO2 Alarm
– SET U GROUP (UTILITIES)
– How to set Wet Activation
– How to set Units
– How to set NOR Safety Stop
– How to set Conservative Factor
– How to set Sampling Rate
– How to set Transmitter Link Code
– SET T GROUP (TIME/DATE)
– How to set Hour Format
– How to set Time
– How to set Date
– Serial Number (Compumask)
– NOR SURF ALT DISPLAYS 1 AND 2
– NOR PLAN MODE
– FLY MODE
– SAT MODE (DESATURATE)
– NOR/GAU LOG MODE
– NOR/GAU HISTORY MODE

OVERVIEW OF DIVE MODE INFORMATION
– Positioning A Transmitter And Mask. Link Interruption Underwater.
– Dive Time Remaining (DTR). No Decompression Dive Time Remaining (NDC). Oxygen Accumulation Time Remaining (OTR). Air Time Remaining (ATR). Air Time Remaining Alarm.
– Ascent Rate Alarm
– Turn And End Pressure Alarms
– Control Of Displays
– Wet Contacts

NOR (NORMAL) TYPE DIVE MODES
– Nor Dive Main And Alt Displays
– Setting Backlight Level
– Nor Dive No Deco Safety Stop
– Decompression Dive Mode
– Violation Modes
– High PO2
– High O2

NOR POST DIVE MODES
– Transition Period
– After The Transition Period

GAUGE OPERATING MODE
– GAU Surface Main And Alt Displays
– GAU Dive Main And Alt Displays

FREE DIVE OPERATING MODE
– Free Surface Main And Alt Displays
– Free Surface Set Menu
– FREE Surface CDT (Count Down Timer) Status
– How to set FREE CDT
– FREE Dive EDT (Elapsed Dive Time) Alarm
– How to set FREE EDT Alarm
– FREE Dive Depth Alarms
– How to set FREE Dive Depth Alarms
– Free Dive Main, CDT, And Alt Displays
– Free Dive Alarms
– Entry Into Deco During A Free Dive

REFERENCE
– Uploading Settings and Downloading Data. PC Compatibility Requirements.
– Mask Preparation and Use
– Care and Cleaning
– Inspectionsand Service
– Battery Replacement
– Installing a Transmitter on a Regulator
– Transmitter Compatibility With Nitrox
– Altitude Sensing And Adjustment
– Charts of No Decompression Limits at Altitude
– Chart of Oxygen Exposure Limits
– Specifications
– Abbreviations
– Inspection/Service Record

POWER
– CompuMask Battery: 1 – 3 vdc, CR2, 0.75 Ahr, Lithium battery (Duracell model DL-CR2 or equivalent)
– Transmitter Battery: 1 – 3 vdc, CR2, 0.75 Ahr, Lithium battery (Duracell model DL-CR2 or equivalent)
– Shelf life: Up to 5 years
– Replacement: User replaceable (annual recommended)
– Use Life (CompuMask): 160 hours with Backlight On Constant at 100% Level
– Use Life (Transmitter): 1 year or 300 dive hours

This operating manual (as detailed in the table of contents) provides all the information from Aeris about the CompuMask HUD. Reading this operating manual completely will address most questions you might have about this HUD (Heads-up Display). You can download and save it for offline use, including viewing it on your device or printing it for your convenience if you prefer a paper version.

Download it by clicking the button below

Helped you out?
Glad to hear that. It would be awesome if you could . . .

Support teklib.com